Paperless drywall firecode x6/23/2023 ![]() ![]() For additional information concerning fire ratings and fire safety, visit our Product Fire, Safety and Use Information page. Shop DensGlass 5/8-in 4-ft x 8-ft Mold Resistant Moisture Resistant Regular Drywall Panel in the Drywall Panels department at. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system. *FIRE SAFETY CAUTION – Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. 2Consult UL Fire Resistance Directory for assembly information The sheathing should be covered by an exterior finish cladding or building felt or equivalent protection if weather conditions will be severe during construction. Local weather conditions will dictate the length of time sheathing may be left exposed. Add to Project Contact Manufacturer Document Contributions Get PDF. (15.9 mm) enhanced proprietary Type X panels for interior wall and ceiling applications. 2 ToughRock Sheathing is manufactured to meet the requirements of ASTM C1396, Section 9, and CSA-A82.27-M and Federal Specification SS-L-30D, Type II, Grade W, X and should be installed per ASTM C1280 and Gypsum Association documents GA-253 and GA-254ġToughRock® Sheathing is not intended for long-term exposure to the weather. USG Sheetrock® Brand EcoSmart Panels Firecode® X Category Drywall Subcategory Drywall Panels Thickness 5/8 in. Also, because it is denser than normal gypsum and paper drywall, it takes longer for the fire to degrade it. Glass fibers are added to the board to help it slow down the fire. The thickness of this drywall is 5/8-inch, including all layers. 5/8” ToughRock Fireguard X Sheathing is UL and ULC classified Type X for use in a variety of fire-rated assemblies. What Is Fire-Rated Type X Drywall Fireproof drywall is the common term its industry name is Type X drywall. ![]() 1 It is designed for direct mechanical attachment to wood or steel framing. 3.2.4 Semi-Solid Gypsum Board Partitions 3.2.5 Solid Gypsum Board Partitions 3.2.6 Adhesive Application to Interior Masonry or Concrete Walls 3.2.7 Application of Gypsum Board to Steel Framing and Furring 3.2.8 Arches and Bending Radii 3.2.9 Gypsum Board for Wall Tile or Tile Base Applied with Adhesive 3.2. 1/2″ ToughRock® Gypsum Sheathing and 5/8” ToughRock® Fireguard X® Sheathing are recommended for use in new building construction or renovation work that is covered by an exterior finish cladding such as vinyl/fiber cement siding, masonry veneer or wire lath stucco. ![]()
0 Comments
Leave a Reply. |